抄録
Thin hardened layer inevitably exist on the polished mechanically treated measured by an ultra-micro hardness tester. In the report the effect of the hardened layer to micro hardness is examined theoretically by FEM computer simulation and experimentally by hardness test using large-sale specimen. The main result is that penetration depth is inevitably needed at least over thickness of hardened layer for pure balk hardness.