運動及び動力伝達機構シンポジウム講演論文集
Online ISSN : 2424-306X
セッションID: 315
会議情報
315 三次元歯面形状誤差の大局的パラメータ抽出とそれによる表現の意味(OS05-1 歯車の検査I)
黒河 周平有浦 泰常
著者情報
会議録・要旨集 フリー

詳細
抄録
The purpose of this research is to extract the meaningful global parameters of 3-dimensional tooth flank topography to evaluate the individual gear accuracy objectively. For this purpose, the tooth flank topography is characterized as the curved surface and the parameters for tooth flank topography are derived from the 3-dimensional measured deviations of tooth flanks. The Oth order form deviation, which is regarded as a general representation of pitch deviations, the parameters for the 1st and 2nd order form deviations are derived. Using those parameters, the surface deviations of a tooth flank is characterized according to the order of the surface. They are calculated from the measured conventional deviations of actual bevel gear flanks and separation processes of measured deviations into four kinds of form deviations are automatically performed. The meaning of their representation is discussed for the parameters of each order form deviations.
著者関連情報
© 2007 一般社団法人 日本機械学会