動力・エネルギー技術の最前線講演論文集 : シンポジウム
Online ISSN : 2424-2950
セッションID: D202
会議情報
D202 中性子ラジオグラフィを用いたダイナミックCT技術によるPEFC内水分布の可視化(OS4 水素・燃料電池),動力エネルギーシステム部門20周年,次の20年への新展開)
和田 大祐村川 英樹杉本 勝美浅野 等竹中 信幸
著者情報
会議録・要旨集 フリー

詳細
抄録
Fuel gas (hydrogen gas) and oxidant gas (air) are supplied to a Polymer Electrolyte Fuel Cell (PEFC) in saturated moist condition to keep a membrane wet. Condensation may occur in the cathode side, since the air is super-saturated by the fuel cell reaction. If the condensed water stay in an electrode, Gas Diffusion Layer (GDL) or gas channels, it may affect on the fuel cell performance. In this study, dynamic CT technology which performed 1 CT per 1 sec was developed, and visualization of three-dimensional water distributions in an operating PEFC was measured by using neutron dynamic CT. As a result, it was confirmed that the developed system can measure three-dimensional water distribution in the PEFC and, condensed water had a significant influence on the fuel cell performances.
著者関連情報
© 2010 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top