主催: 一般社団法人 日本機械学会
会議名: ロボティクス・メカトロニクス 講演会2016
開催日: 2016/06/08 - 2016/06/11
This paper subscribes micro suction-controller array (MISCA) that can be attached to robot hands to hold and release small objects. Micro-channel of MISCA is filled by working fluid, enabling to minimize entire suction switching system. We confirmed that PDMS (poly-dimethylsiloxane) membrane of MISCA deformed by changing pressure inside of the micro-channel. Moreover, MISCA contacted on flat acryl surface showed 1.16 N suction force when the pressure in the micro-channel was -66 kPa. Finally, we successfully demonstrated that MISCA can hold and release 75 g watch and 1 g one yen coin. This small suction system with MISCA will enhance handling ability of robot hands.