スターリングサイクルシンポジウム講演論文集
Online ISSN : 2424-2926
会議情報
C05 宇宙機搭載をめざした小型パルス管冷凍機の評価 : 低温端の振動測定
久志野 彰寛杉田 寛之松原 洋一
著者情報
会議録・要旨集 フリー

p. 101-102

詳細
抄録
We report results from three pulse tube coolers used at around 60 K. All of them were successfully driven in vacuum conditions and showed similar cooling capabilities with flight Stirling and pulse tube coolers. Vibrations at cold heads and linear compressors have been measured and their displacements were revealed to be less tan 10 μm in x, y and z directions. They imply that vibration form the compressor must be dominant in 'integrated' pulse tube coolers.
著者関連情報
© 2003 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top