スターリングサイクルシンポジウム講演論文集
Online ISSN : 2424-2926
会議情報
A07 1kW 級スターリングエンジン発電機の性能改善
関谷 弘志池上 和男大竹 雅久高橋 三餘濱口 和洋山下 巌
著者情報
会議録・要旨集 フリー

p. 27-28

詳細
抄録
Stirling engines take effect on the environment problem arising on a terrestrial scale. The authors have developed the 1kW class Stirling engines for a home-use co-generation system, and have investigated a machine structure including crank mechanism, an electric generator and heat exchangers in order to improve the performance of Stirling engine generator for practical use. This paper describes the development process of the 1kW class Stirling engine generators. The demonstrator is designed as a γ type machine and two functional prototypes are α type machines. The functional prototype developed later is sealed hermetically because a flywheel is built in a crank case. The performance of functional prototype is the highest engine generator efficiency of 16.3% and the maximum electric power of 502W.
著者関連情報
© 2003 一般社団法人 日本機械学会