熱工学コンファレンス講演論文集
Online ISSN : 2424-290X
セッションID: D211
会議情報
D211 ジュール加熱場における流体の透磁率による流動挙動の変化(OS-2:複合対流)
都築 宣嘉木倉 宏成齋藤 義鷹河合 秀樹橋本 学南 和宏越智 英治
著者情報
会議録・要旨集 フリー

詳細
抄録
Numerical calculations for the cavity flow which simulates Joule-heated glass furnace were executed using finite element analysis (FEA) code. The cavity consists of two electrode plates on facing sides and constant temperature wall on the top working as a heat sink. Relative magnetic permeability (μ_r) of molten glass to air was widely varied from 1 to 10. In case μ_r = 1, magnetic permeability is small, unsteady downflows occurred from top surface of the cavity. However, in case μ_r = 10, magnetic permeability is large, a large and steady upflow appeared in the center of cavity. Magnetic permeability largely affected flow characteristics of the cavity, and it may be able to contribute to stable operation of the glass furnace.
著者関連情報
© 2011 一般社団法人 日本機械学会