D211 高発熱密度電子機器の沸騰冷却について(OS-15: 沸騰・凝縮伝熱および混相流の最近の進展(5))
鈴木 康一, 陳 剛, 結城 和久
著者情報
会議録・要旨集 フリー

詳細
抄録
To obtain cooling data for high power electronic devices such as inverter in electric vehicle, subcooled pool boiling has been performed for binary mixtures of ethylene-glycol and water under atmospheric condition. Volume concentration of ethylene-glycol is 30% and 50%. Microbubble emission boiling is observed at above 40K of liquid subcooling and the heat flux increases higher than CHF. The maximum heat flux is 350W/cm^2 at about 200℃. It satisfies the requirements of maximum cooling heat flux of 300W/cm^2 for a power inverter of future electric vehicle. However, the heat flux and heat transfer coefficient are considerably lower than those of water.