熱工学コンファレンス講演論文集
Online ISSN : 2424-290X
セッションID: B221
会議情報
B221 二次元温度場計測を通した高温加熱面の膜沸騰崩壊温度および沸騰熱伝達特性 : 高液サブクール度条件の検討(OS-01:沸騰・凝縮伝熱および混相流の最近の進展(4))
上野 仁裕大竹 浩靖長谷川 浩司
著者情報
会議録・要旨集 フリー

詳細
抄録
The behavior of rewetting on a high superheated and dry surface, focusing on rewetting temperature just as collapse of saturated and subcooled film boiling was investigated experimentally. Saturated and subcooled impingement jet experiments were conducted by using a silver plate with 40.0× 40.0 mm (length × width) and pure water at atmospheric condition. The liquid subcooling was 0, 10, 20, 30, 40, 50 and 75K, respectivelity. Temperature of the test heater was measured by using a commercial separated-type infrared thermometer from a back side of it. The sputtering temperature, i.e., rewetting initiation temperature, was close to the value given by Nishio's correlation, 200℃, in spite of liquid velocity and liquid subcooling.