熱工学コンファレンス講演論文集
Online ISSN : 2424-290X
セッションID: A114
会議情報

基板上の実装された電子部品の発熱量測定
梶田 欣岩間 由希国峯 尚樹
著者情報
会議録・要旨集 フリー

詳細
抄録

Three dimensional numerical analysis is utilized for thermal design of electronic devices. In this calculation, heat productions of electronic component are needed for input values, and they have an important consequence for prediction accuracy. But, it is often the case that the values are imprecision, because it is not well defined to measure or calculate the values at the moment. We developed a measurement method that is used a heatsink with cooling fan and a heat flow sensor. A heat production for a top of the electronic component is measured by the heat flow sensor. Total heat productions are calculated according to a correction algorithm. This measurement is executed in the state that electronic circuit is operated.

著者関連情報
© 2016 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top