材料
Online ISSN : 1880-7488
Print ISSN : 0514-5163
ISSN-L : 0514-5163
既存コンクリート系建築物における鉄筋のガス圧接継手の継手強度の再評価に関する研究
田中 礼治大芳賀 義喜熊谷 元行小澤 昌広
著者情報
ジャーナル フリー

1999 年 48 巻 11 号 p. 1275-1280

詳細
抄録
The strength of gas-pressure welded joint is evaluated as strong as the strength of the using reinforcement. But, many gas-pressure welded joints were damaged in RC and SRC structural buildings at the 1995 Hyogoken Nanbu Earthquake. After earthquake, we picked up 365 test pieces of gas-pressure welded joints from the damaged RC and SRC structural buildings, and those pieces were tested by the tension test. The 12.6% pieces in all test specimens were fractured. Therefore, the strength of gas-pressure welded joints in the existing concrete structural buildings are not able to apply the present evaluation. This paper is a study on the revaluation of strength of gas-pressure welded joints. The strength of gas-pressure welded joints were revaluated by the research data of Hyogoken Nanbu Earthguake and another test data of 23 public experiment institution in Japan. From the research of this study, we took mainly the following conclusions.
(1) The strength of gas-pressure welded joint used in the existing concrete structural buildings were not evaluated as strong as the strength of the using reinforcement.
(2) We proposed the method of revaluation of the strength for gas-pressure welded joints used in the existing concrete structural buildings.
著者関連情報
© 日本材料学会
前の記事 次の記事
feedback