日本口腔インプラント学会誌
Online ISSN : 2187-9117
Print ISSN : 0914-6695
ISSN-L : 0914-6695
原著
インプラントの振動特性に関する基礎的研究
―上部構造体の材質の違いによる影響―
田中 靖二山崎 正登萩原 芳幸小泉 政幸五十嵐 孝義
著者情報
ジャーナル フリー

2002 年 15 巻 4 号 p. 418-424

詳細
抄録
Purpose:In an attempt to evaluate osseointegration of an implant body, a comparison was done on the influence of differences in the material of the superstructure body, on the results of vibration analysis.
Materials and Methods:The measurement sample was a model in which a fixture had been implanted in super-hard plaster. A manufactured conical abutment (CA) and a gold UCLA abutment were placed in the top of the same metal frame. Then, a super porcelain AAA(PFM),Estenia(ES), and UNIFASTⅡ(UⅡ),manufactured for the superstructure body in the form of a mandibular small molar, was connected by torque according to the directions of the manufacturer. The conical abutment was then connected with the fixture. The sample in which the superstructure body was connected with the screw,was the CA. The sample in which the superstructore body was made, was connected with a screw using the gold UCLA abutment. To measure each sample, an acceleration sensor was installed on the side of the tongue. An FFT analyzer was used for Periotest measurement from the buccal side. Differences in torque for the various kinds of abutment were compared according to the influence exerted on the vibration in continuous time, and also in terms of peak frequency.
Results and Discussion:The CA was influenced by differences in the property of the superstructure body material, buffering the vibration resulting from a hammer. In the case of the UA, because an upper structure body was connected with the fixture directly, the vibration characteristics may have been influenced by differences in the property of the material.
著者関連情報
© 2002 公益社団法人日本口腔インプラント学会
前の記事 次の記事
feedback
Top