Diffusion-weighted imaging (DWI) is widely applied for evaluating patients with acute ischemic stroke. However, its display conditions are different among institutions, and reliability of the apparent diffusion coefficient (ADC) has not been validated enough. Recently, we proposed an easy-to-use technique to standardize display conditions, in which window width and level are normalized by the signal intensity of brain tissue on b0 images. We carried out a multi-institutional multivendor study, and revealed that the technique successfully minimized difference in the display condition among institutions and vendors. On the other hand, we found that the ADC value is significantly different among vendors and static magnetic fields, suggesting that the ADC should be evaluated semiquantitatively. Standardization and technical advancement are considered to be necessary to improve reliability of DWI in acute stroke managements.