水環境学会誌
Online ISSN : 1881-3690
Print ISSN : 0916-8958
ISSN-L : 0916-8958
論文
富栄養化堀水の粒状層ろ過の性能に及ぼす設計操作条件の影響
毛利 光男丹羽 千明秋葉 道宏森 忠洋
著者情報
ジャーナル フリー

1995 年 18 巻 10 号 p. 794-802

詳細
抄録
Characteristics and performance of granular media filtration of eutrophicated moat water were studied in the bench-scale equipment to determine the design and operating parameters (AL/T, medium size, filtration rate) for optimum filter operation.
The reasonable aluminum/turbidity ratio (AL/T) was about 0.01 in both terms of achieving sufficient stability of the filter performance and lessening the influence of residual aluminum salt on fish and shellfish in the moat. The 1.2mm size medium had the highest SS removal ratio, but the weight of removed SS was the lowest due to clogging in the short term. The 2.4mm size medium was suited for the removal of the SS which were mostly particles larger than 20 μm and the VSS in influent, making long-term filtration possible. The filtration process of 2.4mm media was expressed in a filtrate equation by Mintz and a conservation equation. Higher filtration rates decreased the SS removal ratio more rapidly and reduced the ultimate deposit (σu). Judging from the calculation result, the filtration rate should be about 100m·d-1 at the high SS concentration of influent in summer and should be about 100-175m·d-1 at the low SS concentration of influent in winter.
著者関連情報
© 1995 公益社団法人 日本水環境学会
前の記事 次の記事
feedback