凝集沈殿処理によるダイオキシン類の形態別除去特性
堤 かおり剱持 由起夫有川 彰浩府中 裕一
著者情報
ジャーナル フリー

2003 年 26 巻 5 号 p. 301-306

詳細
抄録
Coagulation-precipitation treatment using ferric chloride was carried out in wastewater taken from a solid waste incinerator wet scrubbing system. The treated wastewater was fractionated with 1 μm and 0.1μm filter, and the dioxin concentration in each fraction was determinde. The isomer profiles indicated that 1) dioxin concentration in the “<0.1μm” fraction decreased, and 2) dioxin in the “≥0.1,<1μm” fraction between temproary increased by the conagulation process. Hence, it become clear that dioxin particle size increases and dioxin can be removed with conagulation-precipitation treatment. The relationship between dioxin isomer concentrations in montreated warte (X) and treatde water (Y), and Flocculant concentration (A) is expressed by the following regression formula. Y=2.3×1010×(X/A)+1.8 This result suggests that a dioxin concentration of more than 1,000 pg TEQ·l-1 in highly contaminated wastewater can be reduced to below the wastewater effluent regulation value (10 pg TEQ·l-1) by a combination of coagulation-precipitation treatment and membrane filtration.
著者関連情報
© 2003 公益社団法人 日本水環境学会