ANTIGENICITY STUDY OF IODIXANOL, A NEW NON-IONIC CONTRAST MEDIUM
Hiroyuki HATTORIFumie YAMAGUCHIHiroshi OHNOMamoru NOMURA
Author information
JOURNAL FREE ACCESS

1995 Volume 20 Issue SupplementI Pages 117-123

Details
Abstract

Antigenic potential of iodixanol, a new non-ionic contrast agent, was evaluated by systemic anaphylaxis (SA) test and homologous passive cutaneous anaphylaxis (Homo-PCA) test using guinea pigs and IgE mediated heterologous PCA (Hetero-PCA) test using rats passively sensitized with mouse sera. SA test was conducted in guinea pigs sensitized with iodixanol at dose levels of 32 or 320 mgI/kg emulsified with Freund's complete adjuvant, followed by challenge with iodixanol (320 mgI/kg). Four- or 24-hr Homo-PCA test was performed with sera from the sensitized animals. Neither positive SA nor Homo-PCA reaction was observed. Hetero-PCA test was performed with the sera from the mice which were sensitized with iodixanol (32 or 320 mgI/kg) with aluminum hydroxide gel. No positive Hetero-PCA reaction was detected in the sera, followed by challenge with iodixanol (320 mgI/kg). Thus, it is concluded that iodixanol possesses no antigenic potential under the present experimental conditions.