Journal of Veterinary Medical Science
Online ISSN : 1347-7439
Print ISSN : 0916-7250
ISSN-L : 0916-7250
Production and Characterization of Biodegradable Povidone-iodine Microsphere as a Intramammary Disinfectant
Hee-Myung PARK, Hong-Ryul HAN
Author information
JOURNAL FREE ACCESS

2002 Volume 64 Issue 8 Pages 739-741

Details
Abstract
Microspheres composed of biocompatible, biodegradable poly dl-lactide-co-glycolide (DL-PLGA) and Povidone-iodine were evaluated as an intramammary disinfectant delivery system in vitro prior to infusion into mammary glands. Microsphere was prepared by solvent evaporation method and particle size, morphology and in vitro release kinetics were examined. The microspheres were ranged in size from 25 μm to 155 μm (mean diameter = 65.7 μm). Povidone-iodine was dispersed on the surface of microsphere and microsphere was spherical in shape with a smooth surface. The yield of microsphere was 57.3% and the encapsulation efficiency was 69.6%. In in vitro release study, a burst effect (50.9%) was observed during the first two days and a sustained release then continued for the next 28 days. Results of the present study demonstrated that microsphere have the potential for new intramammary disinfectant formulations that can provide increased efficacy of therapy against mastitis pathogens.
Content from these authors
© 2002 by the Japanese Society of Veterinary Science

この記事はクリエイティブ・コモンズ [表示 - 非営利 - 改変禁止 4.0 国際]ライセンスの下に提供されています。
https://creativecommons.org/licenses/by-nc-nd/4.0/deed.ja