Use of an Aortic Stent Graft Extension for the Treatment of Urethral Stricture in a Dog
Jae Hyun BAEYong Hwan KWONYe Chan JUNGJi Mo JUNGHae Beom LEEKi Chang LEENam Soo KIMMin-Su KIM
著者情報
ジャーナル フリー

2013 年 75 巻 10 号 p. 1363-1365

詳細
抄録
A 2-year-old male mixed dog was referred to us for further evaluation and treatment of a 4-week-history of oliguria and abdominal distension after a surgical repair of urethral injury. To relieve the urethral stricture, we placed a self-expanding aortic stent graft extension with a partial coverage with an expanded polytetrafluoroethylene (ePTFE). After the placement of the stent, the dog presented with a normal urinary voiding, despite the presence of urinary incontinence. The current case indicates that the ePTFE-covered, self-expanding ASGE is an effective intervention for the treatment of severe urethral stricture in the dog.
著者関連情報
© 2013 by the Japanese Society of Veterinary Science

この記事はクリエイティブ・コモンズ [表示 - 非営利 - 改変禁止 4.0 国際]ライセンスの下に提供されています。
https://creativecommons.org/licenses/by-nc-nd/4.0/deed.ja