Journal of Veterinary Medical Science
Online ISSN : 1347-7439
Print ISSN : 0916-7250
ISSN-L : 0916-7250
Laboratory Animal Science
Non-contact respiratory measurement in a horse in standing position using millimeter-wave array radar
Takuya MATSUMOTOShigeaki OKUMURASatoshi HIRATA
Author information
JOURNAL OPEN ACCESS
Supplementary material

2022 Volume 84 Issue 10 Pages 1340-1344

Details
Abstract

This study aimed to apply radar technology to a large quadruped animal. We first developed a non-contact respiration measurement system using millimeter-wave array radar for a horse in standing position. Specifically, we measured the respiration of a stationary domestic horse in stables. Simultaneously, we measured the respiration rate using infrared thermography and developed a method for analyzing the radar information while verifying the rate of agreement. Our results suggested that the radar technology detected breathing and accurately measured the respiration of a horse, despite variation in the breathing frequency. To the best of our knowledge, this is the first study to apply a non-contact respiration measurement system using millimeter-wave array radar has been applied to large animals in an upright position, thereby demonstrating its potential application in animal husbandry and welfare.

Content from these authors
© 2022 by the Japanese Society of Veterinary Science

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Previous article Next article
feedback
Top