抄録
Appropriate and effective anesthesia is critical because it has a strong influence on laboratory animals, and its affect greatly impacts the experimental data. Inhalationl anesthesia by endotracheal intubation is currently prevailing in general anesthesia and is prefered over injection anesthesia, especially for large laboratory animals because it is a safe and easy control agent. However it is not common for small laboratory animals because of the high degree of technical skills required. We assessed the capability of use for mice of the endotracheal intubation by using the endoscope system “TESALA AE-C1” and inhalational anesthesia with a ventilator. Endotracheal intubation was successfully performed on all 10 C57BL/6 mice injected with M/M/B: 0.3/4/5 comprised of medetomidine, midazoram and butorphanol, at a dose of 0.3 mg/kg + 4.0 mg/kg + 5.0 mg/kg body weight/mouse, respectively. After the intubated mice were connected with the inhalational anesthesia circuit and the ventilator, vital signs were measured until 15 min after the connection. The data with M/M/B: 0.3/4/5 showed stable and normal values, which indicated that this new endotracheal intubation method was simple, reliable, and safe, which means that this anesthesia is favorable in regard to the animal’s welfare.