Journal of Veterinary Medical Science
Online ISSN : 1347-7439
Print ISSN : 0916-7250
ISSN-L : 0916-7250

This article has now been updated. Please use the final version.

The effects of gel pad thickness on the evaluation of skin structures using ultrasonography in normal dogs
Sothavy CHHAYKiwamu HANAZONOJo KITAHARAAi HORIKenjiro MIYOSHITakaharu ITAMIDaiji ENDOHTetsuya NAKADE
Author information
JOURNAL OPEN ACCESS Advance online publication

Article ID: 21-0086

Details
Abstract

Gel pads are commonly used in skin ultrasonography; however, the effects of their thickness are unknown. This study investigated the effects of pad thickness on measurements of skin thickness in 10 beagle dogs. Sonograms to measure neck skin thickness were captured without pads and using pads with thicknesses of 3, 5, 10, and 20 mm. Without pads, acoustic shading was observed due to air bubbles in the coupling gel. With 20-mm pads, echogenic artifacts were observed on the skin surface. Entry echo with 20-mm pads was significantly higher than with 3-mm pads. This suggests that visibility of the skin structure could be affected when a gel pad is not used or when a thick gel pad is selected.

Content from these authors
© 2021 by the Japanese Society of Veterinary Science

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
feedback
Top