Assessment of the measurement of canine and feline serum fibroblast growth factor-23 concentrations by automated chemiluminescence immunoassay
Hirosumi MIYAKAWAHuai-Hsun HSUMizuki OGAWAYuichi MIYAGAWANaoyuki TAKEMURA
Author information
JOURNAL OPEN ACCESS Advance online publication

Article ID: 21-0566

Details
Abstract

This study compared canine and feline fibroblast growth factor (FGF)-23 concentration measurements between automated chemiluminescence assay (CLEIA) and enzyme-linked immunosorbent assay (ELISA). Seventy serum samples each from dogs and cats were evaluated. FGF-23 measurements by CLEIA significantly correlated with those of ELISA in both dogs and cats. The Bland–Altman test showed that FGF-23 between CLEIA and ELISA had fixed and proportional biases, respectively, in both dogs and cats. Measurements by CLEIA were lower than those of ELISA, especially in higher serum FGF-23 concentrations. This study showed that FGF-23 concentrations in dogs and cats can be evaluated by automated CLEIA. However, FGF-23 cannot be directly compared between CLEIA and ELISA.

Content from these authors
© 2021 by the Japanese Society of Veterinary Science

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.