真空
Online ISSN : 1880-9413
Print ISSN : 0559-8516
ISSN-L : 0559-8516
速報
イオンポンプケーブルの放射線劣化調査
大石 真也, 依田 哲彦, 谷内 友希子, 成山 展照, 建石 剛, 米原 博人, 大熊 春夫
著者情報
ジャーナル フリー

2006 年 49 巻 3 号 p. 132-134

詳細
抄録
  The SPring-8 Storage Ring has been operated since 1997, and the integrated electron beam dose was achieved over 2750 A•hr. Electric cables have been irradiated with the high-intense scattered X-ray from photon absorber, and are damaged. Then we measured the absorbed dose along the laying route of radiation damaged ion pump cable, and compared the result with that of various analyses of the damaged cable. As a result, it was confirmed that absorbed dose correlate closely with mechanical strength, and the melting point of the insulator.
著者関連情報
© 2006 日本真空協会
前の記事 次の記事