肩関節
Online ISSN : 1881-6363
Print ISSN : 0910-4461
ISSN-L : 0910-4461
筋腱疾患
鏡視下骨孔腱板修復術の利点と欠点
酒井 清司
著者情報
ジャーナル 認証あり

2013 年 37 巻 2 号 p. 665-668

詳細
抄録
Background: Arthroscopic trans-osseous suture repair of the rotator cuff (ATOS) is a kind of anchor-less arthroscopic rotator cuff repair. The objective of this study is to assess the characteristics of ATOS.
Methods: From December of 2010 to April of 2012, we performed ATOS after arthroscopic subacromial decompression on thirty-two patients. The size of tear of the rotator cuff was measured by MRI, functional outcome (The points of pain, function, range of motion of Japanese Orthopaedic Association Score), postoperative repair integrity (MRI evaluation by Sugaya's classification), and operation time were researched.
Results: The distribution of size of cuff tear were a bursal side tear, 10 small tears, 8 medium tears, 4 massive tears, and 9 global tears. Each item of the JOA score improved as follows, pain; 9 to 25 points, function; 11 to 18 points, and ROM; 24 to 27 points, respectively. Repair integrity were generally good: type I; 14 cases, type II; 10 cases, type III; 4 cases. Type IV; 3 cases and type V; 1 cases were regarded as failure of cuff repair. The average operation time was 137 minutes, but the data of the latest month was 100 minutes.
Conclusion: The surgical results of ATOS were good. Though the procedure needs maturity, ATOS is not time consuming surgery.
著者関連情報
© 2013 日本肩関節学会
前の記事 次の記事
feedback
Top