日本機械学会論文集 B編
Online ISSN : 1884-8346
Print ISSN : 0387-5016
ソーダ回収ボイラの過熱器における熱流動特性
江崎 秀司川路 正裕/ /TRAN HonghiDEES Charlie
著者情報
ジャーナル フリー

1997 年 63 巻 607 号 p. 993-999

詳細
抄録
Accurate prediction of tube surface temperature is important for determining whether accelerated superheater corrosion will occur in kraft recovery boilers. A heat transfer model, which combines an iterative numerical solution scheme with a more realistic flue gas flow field obtained from the CFD code FLUENT, has been developed to predict the tube, steam and flue gas temperatures in the superheater region. Results of tests performed for a recovery boiler show that temperatures predicted using the model are in good agreement with actual temperatures measured using thermocouples. The presence of a large flue gas recirculation zone above the bullnose is shown to have an adverse effect on the heat transfer in the superheater region.
著者関連情報
© 社団法人日本機械学会
前の記事 次の記事
feedback
Top