2024 Volume 65 Issue 5 Pages 512-517
In this study, experimental investigations were conducted to create fatigue limit diagrams for NSSC180 ferritic stainless steel, which is used for automobile exhaust system parts, subjected to excess deformation, in order to clarify the relationship between the mean stress and fatigue limit. The fatigue tests were conducted under a fixed maximum stress, which allowed a fatigue design diagram to be obtained. The results indicated that the fatigue limit curve has a region where the effect of increasing the mean stress on the decrease in the fatigue limit is more moderate than that predicted by a modified Goodman line. Furthermore, it was found that a fatigue design based on static crack initiation is more appropriate than the modified Goodman line for higher values of mean stress.
This Paper was Originally Published in Japanese in J. Soc. Mater. Sci., Japan 72 (2023) 535–541.