医用画像情報学会雑誌
Online ISSN : 1880-4977
Print ISSN : 0910-1543
ISSN-L : 0910-1543
技術ノート
Cuフィルタを使用した腹部単純X線撮影におけるSchefféの一対比較法を用いたコントラスト評価
和田 悠哉松本 一真小泉 将司琴浦 規子
著者情報
ジャーナル フリー

2022 年 39 巻 4 号 p. 73-77

詳細
抄録

The purpose of this study is to examine the abdominal X-ray image contrast with additional Cu filtration using Scheffé’s paired comparison method. We obtained abdominal phantom images with different Cu filter thickness after dynamic processing. We measured the image contrast of abdominal phantom images and evaluated them using Scheffé’s paired comparison method. The observers were 7 radiological technologists (2 to 33 years of experience, average 15.6 years). Approximately, there was a maximum of 16 % decreasement in the image contrast when we added 0.3 mm Cu filtration. There was no significant difference in Scheffé’s paired comparison method (95 % confidence interval) . From these results, abdominal X-ray with up to 0.3 mm Cu filtration does not decrease visually significant image contrast. Abdominal X-ray with up to 0.3 mm Cu filtration does not decrease visually image contrast.

著者関連情報
© 2022 医用画像情報学会
前の記事 次の記事