Magnetic Resonance in Medical Sciences
Online ISSN : 1880-2206
Print ISSN : 1347-3182
ISSN-L : 1347-3182
Major Papers
Prediction of Sufficient Liver Enhancement on the Gadoxetate Disodium-enhanced Hepatobiliary Phase Imaging Using Transitional Phase Images and Albumin–bilirubin Grade
Yasuo TakatsuMasafumi NakamuraSatoshi KobayashiTosiaki Miyati
著者情報
ジャーナル オープンアクセス

2021 年 20 巻 2 号 p. 152-159

詳細
抄録

Purpose: To investigate whether the contrast enhancement effect in hepatobiliary phase (HBP) images can be predicted using transitional phase (3-min delay) images on liver magnetic resonance imaging (MRI) based on the quantitative liver–spleen contrast ratio (Q-LSC) and albumin–bilirubin (ALBI) grade.

Methods: Overall, 212 patients (124 men and 88 women; mean age 66.7 ± 11.1 years) who underwent blood tests (assessed within 1 month of performing MRI) were included; patients with diffuse tumor, hepatectomy, splenectomy, Gamna–Gandy bodies in the spleen, and movement artifacts were excluded. Q-LSC was calculated using the signal intensity of the liver divided that of the spleen. Q-LSC > 1.5 (cut-off value) indicates a relatively higher sensitivity for detecting of hepatic lesions. To predict the contrast enhancement effect in HBP using Q-LSC of 3-min delay images, Q-LSC of 10- and 15-min delay images were compared for each ALBI grade based on Q-LSC of 3-min delay images. Furthermore, to verify the accuracy of this prediction, the proportion of cases with Q-LSC > 1.5 in 10- and 15 min delay images was calculated based on Q-LSC on 3-min delay images.

Results: The higher the Q-LSC on the 3-min delay image, the higher was the Q-LSC on its 10- and 15-min delay images. The proportion of cases with Q-LSC > 1.5 in 10- and 15-min delay images was higher for ALBI grade 1 than for ALBI grades 2 and 3 even in the same Q-LSC on 3-min delay images. Q-LSC was <1 in a 3-min delay image and <1.5 in a 15-min delay image in 62.2% of patients with ALBI grade 1 and 82.1% of patients with ALBI grades 2 and 3.

Conclusion: The liver contrast enhancement effect in HBP images could be predicted using a 3-min delay image based on Q-LSC and ALBI grade.

著者関連情報
© 2020 by Japanese Society for Magnetic Resonance in Medicine

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/