Neurologia medico-chirurgica
Online ISSN : 1349-8029
Print ISSN : 0470-8105
ISSN-L : 0470-8105
髄液漏に対する経皮的L-Pシャント術の有効性について
自験3症例と文献的考察
石渡 祐介塩沢 亮夫市川 輝夫小島 康弘稲田 良宜
著者情報
ジャーナル フリー

1985 年 25 巻 11 号 p. 923-927

詳細
抄録
Three cases of cerebrospinal fluid (CSF) leakage were successfully treated by percutaneous lumboperitoneal (L-P) shunting. Case 1 showed rhinorrhea secondary to a head injury. Case 2 had CSF leakage through the operative wound due to status post intraspinal dural tearing, and Case 3 had CSF leakage through a necrotic wound secondary to brain radiotherapy. The important points for the postoperative management of the patient are as follows: 1) posture of the patient, 2) frequent skull X-rays, 3) removal of shunt system when intracranial low pressure syndrome occurs, and 4) removal of shunt system approximately 3 weeks after operation when hydrocephalus is not present. No serious complications or recurrence were observed in the 3 cases.
Thirty-one cases of CSF leakage managed by percutaneous L-P shunt were reviewed. Twentynine cases were successfully treated. The remaining 2 cases failed to improve. No serious complications were observed in any of the cases. Percutaneous L-P shunt appears to be an effective method for the management of CSF leakage.
著者関連情報
© 社団法人 日本脳神経外科学会
前の記事 次の記事
feedback