体性知覚誘発電位の頭蓋外血行再建術における術中モニターとしての応用
佐々木 雄彦武田 利兵衛小笠原 俊一瓢子 敏夫岡田 好生井出 渉下道 正幸中村 順一藤田 一哉末松 克美
著者情報
ジャーナル フリー

1989 年 29 巻 4 号 p. 280-284

詳細
抄録
Intraoperative somatosensory evoked potentials (SEPs) were measured in 17 patients during 21 extracranial revascularization and related procedures. The operations included 13 carotid endarterectomies (CEAs), two cervical internal carotid ligations, one vertebral artery (VA) clipping, one VA-common carotid artery (CCA) transposition, and four temporary balloon occlusion tests (TBOTs). Three of the 13 CEAs (23%) showed reduced amplitude and delayed latency of primary cortical SEPs during clamping of the carotid artery, followed by their recovery after emplacement of the internal shunt. Flattening of SEPs during clamping of the CCA was observed in the case of VA-CCA transposition; however, SEPs returned to normal immediately after insertion of a biballoon indwelling shunt into the CCA. One of the four TBOTs showed alteration of SEPs during balloon occlusion of the subclavian artery proximal to the origin of the VA. In the others, SEPs remained stable during the entire procedure. Only one transient intraoperative ischemic complication was encountered among the cases of CEA. It was detected through flattening of SEPs, which led to the discovery of an internal shunt obstruction. Carotid stump pressure was also measured in 12 CEAs and two TBOTs, and seven of these 14 had pressure ≤50 mmHg. Four of the seven had carotid stump pressure ≤30 mmHg, and three of these four also showed altered SEPs. SEPs remained stable if the collateral flow was sufficient during vascular occlusion and showed obvious alteration when the blood flow was reduced to below the threshold. The authors conclude that monitoring of SEPs during extracranial revascularization is very useful.
著者関連情報
© 社団法人 日本脳神経外科学会
前の記事 次の記事
feedback
Top