日大医学雑誌
Online ISSN : 1884-0779
Print ISSN : 0029-0424
ISSN-L : 0029-0424
特集 「最近の脳科学」
光脳機能イメージングの進歩
酒谷 薫片桐 彰久横瀬 憲明五十嵐 崇浩星野 達哉藤原 徳生村田 佳宏片山 容一岡本 雅子檀 一平太
著者情報
ジャーナル フリー

2011 年 70 巻 3 号 p. 145-149

詳細
抄録
Measurement of multichannel continuous-wave near-infrared spectroscopy (CW-NIRS) is dependent on the modified Beer-Lambert law, which includes optical path length (PL) as an essential parameter. PLs are known to differ across different head regions and between individuals, but the distribution of PLs for the whole head has not been evaluated so far. Thus, using time-resolved near-infrared spectroscopy (TR-NIRS), we measured the optical characteristics, including PL, scattering coefficients (μls), and absorption coefficients (μa) at three wavelengths (760, 800, and 830 nm). We then constructed maps of these parameters on the surface of the subject′s head. While the PLs in nearby channels are similar, they differ depending on the regions of the head. The PLs in the region above the Sylvian fissure tended to be shorter than those in the other regions at all of the wavelengths. The difference in the distribution of PLs may be attributed to differences in tissue absorption and scattering properties. The current study suggests the importance of considering PL differences in interpreting functional data obtained by CW-NIRS.
著者関連情報
© 2011 日本大学医学会
前の記事 次の記事
feedback