気泡塔型曝気装置による排水処理性能の評価
田中 孝国武笠 巨尭川田 裕子
著者情報
研究報告書・技術報告書 フリー

2012 年 45 巻 p. 117-122

詳細
抄録
As domestic waste water becomes the high density, treatment of waste water using septic tank gradually became difficult. Therefore, we showed a newly pretreatment unit (Mashiko-Clean type III) for septic tank. This characteristic of this unit is a bubble column type aerator of three towers, and it has strong aerating system. In this paper, we evaluated an ability of waste water treatment from various parameters with water analysis. As a result, this unit has degradability of carbon compounds in simulation waste water. COD and BOD were always less than a discharge lower limit value. On the other hand, there was not an anaerobic space, this unit could not removal nitrogen (nitrite nitrogen) and phosphorus compounds. To give the performance of this unit conventionally, we must improve setting (or auditioning) of the anaerobic areas and circulation function between the towers.