Laser Absorption Spectroscopy for Diagnostics of a Neutral Helium Beam
Atsushi OKAMOTOKatsuhiro SHINTOSumio KITAJIMAMamiko SASAO
著者情報
ジャーナル フリー

2007 年 2 巻 p. S1044

詳細
抄録
The density resolution of a measurement system using laser absorption spectroscopy is evaluated in order to diagnose a fraction of metastable helium atoms (2 3S1) in a neutral helium beam. Experiments performed in a hollow cathode device show that the density resolution of the present system is about 5 × 1013 m-3 for a 1 m absorption length. Optimization of absorption scheme and improvements of signal detection are suggested, which shows that laser absorption spectroscopy is a promising diagnostic method for a neutral helium beam.
著者関連情報
© 2007 by The Japan Society of Plasma Science and Nuclear Fusion Research