Plasma and Fusion Research
Online ISSN : 1880-6821
ISSN-L : 1880-6821
Rapid Communications
Improvement of Field Accuracy and Plasma Performance in the RT-1 Device
Yoshihisa YANOZensho YOSHIDAJunji MORIKAWAHaruhiko SAITOHHiroyuki HAYASHITatsunori MIZUSHIMA
著者情報
ジャーナル フリー

2009 年 4 巻 p. 039

詳細
抄録
To improve the accuracy of the magnetic field of Ring Trap-1 (RT-1), we have constructed a system of correction coils to cancel the geomagnetic field and control the attitude of the floating magnet. Without the geomagnetic field canccellation, the floating magnet tilts about 1.4 degrees. The previous prototype correction coils have been replaced by new coils that are much larger and farther from the chamber, so the error field due to the multipole components of the correction field is reduced by a factor of 30 (from 2.6% to 0.1% of the confinement field near the edge region). A significant improvement in plasma confinement has been observed (the stored energy of the plasma has been increased by a factor of 1.5).
著者関連情報
© 2009 by The Japan Society of Plasma Science and Nuclear Fusion Research
前の記事 次の記事
feedback
Top