日本生理学会大会発表要旨集
セッションID: 1P113
会議情報
S90 Heart & circulation
新しい定量的赤血球変形能測定装置の完成
上坂 伸宏小山 哲司丸山 徹関 律子オーレア エドガー塩 Hideo
著者情報
会議録・要旨集 フリー

詳細
抄録
We have developed a quantitative filtration apparatus to evaluate erythrocyte deformability, using a precision metal filter (nickel mesh) which we developed. The filtration system consists of a test unit (a vertical glass tube equipped with a nickel mesh at the bottom end), a negative pressure supply unit, and a measurement control and data analysis unit. The vertical-tube is connected to an air tank or reservoir through electromagnetic valves inside the negative pressure supply unit. The test material is sucked into the filter through the action of decreasing negative pressure. The device automatically gives a liquid level (height)-time relation and a pressure-flow rate relation, similar to gravity-based filtration. Unlike the gravity-based system, the experimental performance of this system is very good and reproducible. Nowadays, the physiologic significance and clinical benefit of nickel mesh filtration is evident. Thus, we believe that our new, highly quantitative and convenient apparatus will contribute to the evaluation of erythrocyte deformability for biorheology and related fields of medical science. [Jpn J Physiol 54 Suppl:S92 (2004)]
著者関連情報
© 2004 日本生理学会