脳卒中の外科
Online ISSN : 1880-4683
Print ISSN : 0914-5508
ISSN-L : 0914-5508
原  著
動脈瘤内流れとaspect ratio(aneurysm depth/neck width)の相関
氏家 弘比嘉 隆佐々木 久里吉本 成香堀 智勝
著者情報
ジャーナル フリー

2004 年 32 巻 5 号 p. 351-355

詳細
抄録
We carried out flow visualization studies and measurement of intraaneurysmal flow velocity using a set of three-dimensional bifurcation aneurysm models of various aspect ratio (AR=dome/neck). The aneurysm models were made by an acryl according to computer specification. Flow visualization was performed using the dye injection method. Stream lines in the aneurysm models were monitored and evaluated under various flow ratios into the branches. A mean transit time was calculated by height-over-area method from the time-related concentration of the injected dye in the aneurysm that can be fitted to the exponential curve. Fundamental aneurysm flow was composed of inflow, circulation flow and outflow. A certain asymmetry of the flow ratio was necessary for a significant intraaneurysmal circulation to develop. Mean transit times correlated well with aspect ratio: 5.90 at AR1.0, 17.74 at AR 1.5, 38.36 at AR 2.0 and 75.96 at AR 3.5. Mean transit times became dramatically slow when AR changed from 1.5 to 2.0 and almost stagnant flow was noticed at dome side of aneurysm with AR 3.5.
著者関連情報
© 2004 一般社団法人 日本脳卒中の外科学会
前の記事 次の記事
feedback
Top