金属表面技術
Online ISSN : 1884-3395
Print ISSN : 0026-0614
ISSN-L : 0026-0614
低濃度クロムメッキ液中の塩化物の析出物に及ぼす影響と除去法
小西 三郎由利 隆英
著者情報
ジャーナル フリー

1975 年 26 巻 6 号 p. 268-272

詳細
抄録
The effects of chloride on chromium deposits in low concentration CrO3 bath (CrO3 50g/l, H2SO4 0.5g/l, and Na2SiF6 0.5g/l) and its removal were investigated, and the following results were obtained. When copper was a substrate, parts of no plating due to low current density were corroded at 10mg/l of chloride concentration. The area of the corroded parts was enlarged when the chloride concentration was higher, and finally, bright chromium plating was not obtained at a chloride concentration of higher than 30mg/l. However, in bright nickel plating, the covering power was not much decreased up to 100mg/l of chloride concentration and the corrosion of substrate and decrease of brightness were not observed. The chloride in the chromium plating bath was oxidized at anode and removed under ordinary plating conditions, and also it was proved to be removed by the addition of lead peroxide, which would suggest that the chloride mixed in the plating solution was decomposed by the lead peroxide produced at anode during and at a standstill of plating operation so that it was not a very harmful impurity unless its presence was in too much quantity for a while.
著者関連情報
© (社)表面技術協会
前の記事 次の記事
feedback
Top