表面技術
Online ISSN : 1884-3409
Print ISSN : 0915-1869
ISSN-L : 0915-1869
鉛フリーはんだにおけるイオンマイグレーションの水晶振動子マイクロバランス法による in situ 評価
中村 誠田中 浩和吉原 佐知雄白樫 高史
著者情報
ジャーナル フリー

1999 年 50 巻 12 号 p. 1142-1146

詳細
抄録

Ionic migration often observed in the presence of moisture causes short circuits between electrodes on printed circuit boards and reduces reliability. Many reports suggest that anode dissolution rate and cathode deposition rate affect ionic migration time when short circuits occur. Therefore, to analyze these ionic migration processes, in situ measurement of anode and cathode surface reactions is indispensable. We have already reported that in situ measurement of silver, copper, or solder migration in de-ionited distilled water is possible by applying a quartz crystal microbalance (QCM). We report here the migration processes of lead-free solder in air and nitrogen atmospheres by means of QCM. We found that the main deposited component of lead-free solder is tin, that of older lead-based solders is lead, and that lead-free solder is less prone to migration than older lead-based solders.

著者関連情報
© (社)表面技術協会
前の記事 次の記事
feedback
Top