SICE Annual Conference Program and Abstracts
SICE Annual Conference 2002
会議情報

Construction of the Measurement System and its Experimental Study for Diagnosing Cerebral Functional Disorders Using Eye-Sensing HMD
Hirotake IshiiYoshinobu OkadaHiroshi ShimodaHidekazu Yoshikawa
著者情報
会議録・要旨集 フリー

p. 276

詳細
抄録
Ocular information such as pupil size, eyeblink or eye gaze point can be utilized for diagnosis of cerebral function disorders. There are a lot of methods of measuring ocular information, but accuracy and simplicity are required to be applied for diagnosis of cerebral function disorders. In this paper, the relationship between ocular information and cerebral function disorders is described first, followed by the review of methods of measuring ocular information. And system configuration of Eye-Sensing HMD which can not only provide three-dimensional images but also measure ocular information is described. Then measurement system to measure ocular information by using Eye-Sensing HMD and its experimental study for diagnosing cerebral function disorders are described.
著者関連情報
© 2002 SICE
前の記事 次の記事
feedback
Top