分割測定法による回転精度検査用標準器の形状評価とその不確かさ推定
佐藤 浩志渡部 司藤本 弘之
著者情報
ジャーナル フリー

2013 年 49 巻 3 号 p. 386-393

詳細
抄録
In order to evaluate the performance of ultraprecision machining, precise and accurate roundness or form profile measurements of a glass hemisphere are required. In such measurements, the multistep method is a commonly used self-calibration method. This method allows the roundness error of the workpiece to be separated from the spindle error of the machine. Recently, the phase combination method has also been used for high-accuracy measurements. This method produces results equivalent to those obtainable using a large number of steps, by combining two sets of results for different smaller numbers of steps. However, there have been no reports describing the uncertainties associated with the estimated roundness profiles using these methods. If the required accuracy is above the specifications, it is necessary to measure of a larger number of steps, which is both time consuming and leads to wear of the workpiece. This paper describes the estimated uncertainty in the profile for roundness measurements using both the multistep and phase combination methods. Based on the estimated uncertainty, the optimum number of steps to achieve a specific level of precision can then be predicted. Furthermore, for the phase combination method, the optimum combination of step numbers is suggested.