Sessile Organisms
Online ISSN : 1883-4701
Print ISSN : 1342-4181
ISSN-L : 1342-4181
発電所の汚損生物対策技術の展望
坂口 勇
著者情報
ジャーナル フリー

2003 年 20 巻 1 号 p. 15-19

詳細
抄録
This paper reviews biofouling control procedures in Japanese power station cooling water systems. Antifouling paints and chlorination are widely used to prevent biofouling. Silicone-based coatings and self-polishing paints containing Cu2O are used commonly as antifouling coatings. Silicone-based paints are very effective under high water velocity. There are several kinds of cleaning and inspection robots to remove fouling organisms in intake culverts. Antifouling methods for condensers comprise online sponge ball cleaning, back wash, and self-cleaning debris filters. Electro-conductive paint and electrochemical methods are used in limited areas in cooling water systems. A robot has been developed for cleaning and inspection of condenser tubes.
著者関連情報
© 日本付着生物学会
前の記事 次の記事
feedback
Top