抄録
A wet classifier with laminar flow was fabricated based on the principle that the settling location of a particle depends on its diameter. The fabricated classifier produced a sharper particle size distribution profiles with respect to diameter than those obtained using conventional classifiers for particles with diameters ranging from 0.5μm to 5μm. In this paper, the major characteristics of the wet cassifier with laminar flow are discussed, theoretical calculations for the design of the system are done, and the calculated results are compared with the experimental results.