Spine Surgery and Related Research
Online ISSN : 2432-261X
ISSN-L : 2432-261X
ORIGINAL ARTICLE
Rate and Factors Associated with Misplacement of Percutaneous Pedicle Screws in the Thoracic Spine
Takeshi Sasagawa
著者情報
ジャーナル オープンアクセス

2023 年 7 巻 2 号 p. 155-160

詳細
抄録

Introduction: Thoracic percutaneous pedicle screw (PPS) fixation is technically challenging because of the complexity of the spinal anatomy involved. Furthermore, owing to the proximity of critical neurovascular structures, serious complications have been reported because of misplaced thoracic pedicle screws. Therefore, it is important to know the factors associated with the misplacement of thoracic PPS, but there have been few reports to date.

Methods: The present study included 663 PPSs inserted from T4 to T12 in 127 patients. The accuracy of pedicle screw placement was assessed using computed tomography (CT) scans conducted within two weeks postoperatively. We compared the screws in the misplaced group (Group M) and the optimal placed group (Group O) for sex, age, body mass index, the consecutive surgery numbers, type of disease, instrumented level, laterality, the pedicle diameter, the inclination angle of the transverse process, and Hounsfield units (HU) at the base of the transverse processes of the instrumented vertebrae.

Results: Screw misplacement was observed in 28 (4%) of 663 screws on CTs conducted within two weeks postoperatively. In univariate analysis, there was a statistically significant difference between Group M (n=25) and Group O (n=638) for insertion level, the pedicle diameter, and the HU value of the transverse process. In multivariate logistic regression analysis, T4-6 level (T4-6; odds ratio [OR]=12.083, 95% confidence interval [CI]: 3.219-45.355) and greater HU value at the transverse process (OR=1.009, 95% CI: 1.004-1.014) were identified as independent factors associated with the misplacement of thoracic PPS.

Conclusions: The misplacement of thoracic PPS was observed in 28 (4%) of 663 screws. The vertebral level (T4-6) and greater HU values at the base of the transverse process were identified as independent factors associated with the misplacement of thoracic PPS.

Fullsize Image
著者関連情報
© 2023 The Japanese Society for Spine Surgery and Related Research.

SSRR is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. Anyone may download, reuse, copy, reprint, or distribute articles published in the journal for not-for-profit purposes if they cite the original authors and source properly. If you remix, transform, or build upon the material, you may not distribute the modified material.
https://creativecommons.org/licenses/by-nc-nd/4.0/
前の記事 次の記事
feedback
Top