構造工学論文集 A
Online ISSN : 1881-820X
鋼・木構造
L字形材をボルト接合した鋼板パネルにおけるボルト間隔が補剛効果に与える影響に関する解析的研究
藤田 翔吾山口 隆司松村 政秀
著者情報
ジャーナル フリー

2016 年 62A 巻 p. 726-736

詳細
抄録
Installing stiffener is effective to prevent plate buckling of plate panels. When focusing on a L-shaped member connected to the plate by high strength bolts, past experimental results reveal strengthening effects equal to welded stiffener can be obtained by the L-shaped member bolted. However, design method of the L-shaped member is not established yet. Then investigated in this study is strengthening effects of the L-shaped member by focusing on bolt intervals and bolt layout through FEM analysis. It is concluded the L-shaped members bolted are effective for plate buckling prevention regardless of tightening bolt force and the bolt intervals are decided so that buckling of the plate panel between the bolts not occur.
著者関連情報
© 2016 公益社団法人 土木学会
前の記事 次の記事
feedback
Top