Measurement of Intrahepatic Shunted Blood Flow by Ethanol-1-14C Method as Compared with D-Galactose-1-14C Method
SHOZO NAKAMURAGEN YOSHIDAYOSHIAKI TAKEZAWATAKASHI SATO
著者情報
ジャーナル フリー

1976 年 119 巻 4 号 p. 345-352

詳細
抄録
Ethanol-1-14C method for the measurement of intrahepatic shunted blood flow was compared with the method of continuous infusion of D-galactose-1-14C. In controls, in chronic hepatitis, and in hepatic cirrhosis, per cent intrahepatic shunt measured by the ethanol-1-14C method was about a half or one-third of that measured by the D-galactose-1-14C method. Study of radioactivity-dye con-centration ratio of the blood sampled from the inferior vena cava showed that per cent intrahepatic shunt was underestimated by the ethanol-1-14C method because of permeability of ethanol-1-14C through the capillaries. In patients with hepatic carcinoma, in whom the carcinomatous tissue was supplied mainly by the hepatic artery, there was no significant difference in per cent intrahepatic shunt between both methods.