IEICE Transactions on Electronics
Online ISSN : 1745-1353
Print ISSN : 0916-8524
Special Section on The Forefront of 21st Century Organic Molecular Electronics
Conducting Polymer Based Nucleic Acid Sensor for Environment Monitoring
Bansi Dhar MALHOTRANirmal PRABHAKARPratima R. SOLANKI
著者情報
ジャーナル 認証あり

2008 年 E91.C 巻 12 号 p. 1889-1893

詳細
抄録
Nucleic acid sensor based on polyaniline has been fabricated by covalently immobilizing double stranded calf thymus (dsCT) DNA onto perchlorate (ClO-4) doped polyaniline (PANI) film deposited onto indium-tin-oxide (ITO) glass plate using 1-(3-(dimethylamino) propyl)-3-ethylcarbodiimide hydrochloride (EDC)/N-hydroxyl succinimide (NHS) chemistry. These dsCT-DNA-PANI/ITO and PANI/ITO electrodes have been characterized using square wave voltammetry, electrochemical impedance, and Fourier-transform-infra-red (FTIR) measurements. This disposable dsCT-DNA-PANI/ITO bioelectrode is stable for about four months, can be used to detect arsenic trioxide (0.1ppm) in 30s.
著者関連情報
© 2008 The Institute of Electronics, Information and Communication Engineers
前の記事 次の記事
feedback