Abstract
This paper proposes an efficient design algorithm for power/ground (P/G) network synthesis with dynamic signal consideration, which is mainly caused by Ldi/dt noise and Cdv/dt decoupling capacitance (DECAP) current in the distribution network. To deal with the nonlinear global optimization under synthesis constraints directly, the genetic algorithm (GA) is introduced. The proposed GA-based synthesis method can avoid the linear transformation loss and the restraint condition complexity in current SLP, SQP, ICG, and random-walk methods. In the proposed Hybrid Grid Synthesis algorithm, the dynamic signal is simulated in the gene disturbance process, and Trapezoidal Modified Euler (TME) method is introduced to realize the precise dynamic time step process. We also use a hybrid-SLP method to reduce the genetic execute time and increase the network synthesis efficiency. Experimental results on given power distribution network show the reduction on layout area and execution time compared with current P/G network synthesis methods.