Radical Formation by Grinding of Commercial Tablets according to Hospital and Pharmacy Prescription
Masayuki KUZUYAShin-ichi KONDOTakaaki ISHIKAWAYouji FURUTAHideki ARAMAKIYasushi SASAIYukinori YAMAUCHI
Author information
JOURNAL FREE ACCESS

2005 Volume 125 Issue 4 Pages 389-396

Details
Abstract
  We examined mechanoradical formation in the grinding process of commercial tablets using electron spin resonance (ESR). Mechanoradicals were detected in all tested samples (23 types of commercial tablets) when the ball-milling of tablets was conducted under anaerobic conditions and some were fairly stable even in air. Thus the grinding may cause changes in the physicochemical properties of ingredients included in commercial tablets. Because high quality is demanded in pharmaceuticals, these results suggest more caution should be taken in the grinding of commercial tablets in hospitals and pharmacies.