顎顔面補綴
Online ISSN : 2435-0389
Print ISSN : 0389-4045
28 巻, 2 号
選択された号の論文の16件中1~16を表示しています
原著論文
  • 上田 康夫, 田村 信太郎, 大畑 昇, 井上 農夫男
    2005 年 28 巻 2 号 p. 39-45
    発行日: 2005年
    公開日: 2025/06/18
    ジャーナル フリー
    It is necessary to remove artifacts caused by metal in the mouth in order to make a living body model from three-dimensional CT images. This has become a problem that cannot be ignored, because in recent years CT scanners have become more efficient and the number of images output has increased greatly. So, to assist this work, we examined a method of automatically detecting of artifacts on the basis of a change of CT value. To catch artifacts, we examined 11,991 CT images of 147 samples taken in the past, and traced changes of range 1 (CT value from -1024 to -961), range 2 (CT value from -960 to -897) and range 17 (CT value from 0 to 63).
    As a result, we could automatically detect more than 70 % of slice images which had artifacts.
  • 服部 麻里子, 隅田 由香, 木村 晋太, 向山 仁, 谷口 尚
    2005 年 28 巻 2 号 p. 46-58
    発行日: 2005年
    公開日: 2025/06/18
    ジャーナル フリー
    顎顔面リハビリテーションにおいて発話能力の評価は極めて重要である.我が国では単音節発語明瞭度検査が広く用いられているが,聞き取り検査に時間と労力がかかること,また人の耳による主観的検査であり,聞き取り検査者の能力によって結果が変化することが欠点である.そこで聞き取り検査を必要としない発語明瞭度検査法を開発する必要があると考え.本研究を行った.コンピューター音声認識技術を用いた発語明瞭度自動検査システムを開発し,健常者10人と上顎欠損患者17人の検査を行った.患者の検査結果は従来法による発語明瞭度検査結果と比較した.今回開発された発語明瞭度自動検査システムはどの被験者においても問題なく使用することができ,聞き取り検査を必要としないため検査後ただちに検査結果を得ることができた.健常者では三日間の測定結果に有意差は見られなかった.欠損患者では義歯なしの状態において自動検査システムの結果と従来法による発語明瞭度に強い相関がみられた.義歯ありの状態では相関がみられなかったが,これらの結果は発語明瞭度自動検査システムが,聞き取り検査を必要としない発語明瞭度検査システムとして患者の発話能力の評価に用いることができる可能性を示唆している.
  • 南 克浩, 小野 高裕, 鈴木 慎也, 城下 尚子, 森 悦秀, 應谷 美幸, 中澤 光博, 清水 英孝, 野首 孝祠, 由良 義明
    2005 年 28 巻 2 号 p. 59-68
    発行日: 2005年
    公開日: 2025/06/18
    ジャーナル フリー
    The purpose of this study was to evaluate subjectively and objectively the masticatory function of patients with implant-supported mandibular dento-maxillary prostheses. Three patients underwent partial resection of the mandible for the treatment of oral carcinomas involving gingiva, floor of the mouth and/or tongue. Occlusal reconstruction was achieved using an overdenture type dento-maxillary prosthesis supported by endosseous implants. Thereafter, masticatory function was assessed by a questionnaire, masticatory efficiency of a gummy jelly and maximal occlusal force. According to the analysis of questionnaires, all patients were satisfied with their prosthesis. The masticatory efficacy and maximal occlusal force were improved in all patients, but the improvement was dependent on the defect of the mandible, the condition of the upper teeth and the morbidity of the tongue.
    These results indicate that our methods to measure masticatory function are useful to demonstrate the efficacy of implant-supported mandibular prostheses.
研究論文
  • 野村 隆祥, 川口 浩司, 佐藤 淳一, 八木 正聡, 園山 智生, 石井 宏昭, 松浦 正朗, 瀬戸 晥一
    2005 年 28 巻 2 号 p. 69-77
    発行日: 2005年
    公開日: 2025/06/18
    ジャーナル フリー
    For patients with dentulous maxillary defects, residual teeth are especially significant as the most important retentive sources. Therefore, one of the most important factors is the design of retainers for the preservation of residual teeth. Case 1 was a 42-year-old female with a hemi-maxillary defect, first examined in 1982. Her first maxillary prosthesis had a multiple T-type bar cast clasps fabricated in our Department of Oral and Maxillofacial Surgery, Tsurumi University in 1983, and was used for 18 years. Subsequently, a new maxillary prosthesis was fabricated by the same design after one of her six maxillary teeth was lost. Case 2 was a 26-year-old female with an anterior-maxillary defect, first examined in 1982, and already fitted with a maxillary prosthesis with wire clasps. A new metal-based maxillary prosthesis with three T-type bar cast clasps was fabricated in 1984. This new prosthesis was applied with no tooth loss for over 20 years.
    A clinical evaluation of these case reports suggested that the passive retainer of single or multiple Roche bar-clasps for maxillary prostheses are effective means to preserve the residual teeth and to retain the prosthesis.
  • 小栁 進祐, 山本 宜明, 津江 文武, 亀岡 佳代, 森 宣昭, 清水 博史, 髙橋 裕
    2005 年 28 巻 2 号 p. 78-83
    発行日: 2005年
    公開日: 2025/06/18
    ジャーナル フリー
    The patient was a 62-year-old woman with left maxillary defect and who was totally edentulous, who had undergone a left partial maxillectomy 25 years ago. A dento-maxillary prosthesis with open type obturator was fabricated. Elastic polyester material was used for the obturator and light polymerized resin was used for the palatal denture plate. The weight of the prosthesis could be reduced because the thickness of the obturator and the palatal denture plate was controlled.
  • 山ロ 能正, 井原 功一郎, 山下 佳雄, 重松 正仁, 辻 光弘, 式守 道夫, 後藤 昌昭
    2005 年 28 巻 2 号 p. 84-90
    発行日: 2005年
    公開日: 2025/06/18
    ジャーナル フリー
    Ready-to-use applicators and spacers are now available for radiotherapy. However, there are cases in which a more sophisticated device is required to meet highly specific therapeutic needs: cases, as in the maxillofacial region, where radiation is applied in a tightly defined site which is part of a complex structure or cases where a precise distance must be maintained between irradiation source and target. We report two applicators that we have devised in our department for specific purposes. One applicator, equipped with a 137Cs small radiation source, was for intracavitary irradiation on an oral cavity tumor, and another for surface irradiation on a penis tumor, both with built-in shield effect to keep healthy tissues surrounding the lesion from accidental exposure to radiation. In the oral tumor case, the applicator itself was made of lead alloy, which has a natural radiation shielding effect, and the possibility of peri-lesion healthy tissues becoming exposed to radiation was minimized. To reduce the radiation dose that the radiologist would be exposed to, the fastening and detaching of the small radiation source was made as easy as possible by an attachment device. In the penis tumor case, a shape-specific applicator was made of acrylic board, fastening of a small radiation source thereon was also made easy, and sufficient shielding was built in to protect the testes from exposure. We have had good results by using these applicators.
  • 天野 優一郎, 尾澤 昌悟, 田中 貴信, 宮前 真, 津田 賢治, 岡崎 祥子, 寺本 清峰
    2005 年 28 巻 2 号 p. 91-96
    発行日: 2005年
    公開日: 2025/06/18
    ジャーナル フリー
    A light-polymerized resin for denture base was used for fabricating the obturator part of an immediate post-surgical maxillary prosthesis. A clear MMA resin base and retainers were prefabricated based on the pre-surgical maxillary model. One week after the surgery, the obturator part was molded directly to a patient maxillary defect using the light-polymerized resin. After polymerization of the obturator part, a tissue conditioning material was applied to improve tissue adaptation. Then, another light-polymerized resin for artificial teeth was appended to the prosthesis for recovering esthetic and masticatory function. This method has advantages of not irritating the post-surgical tissue of the patient, ease of handling by dentists, and shorter chair-time compared to the conventional method.
  • 久保 吉廣, 中川 弘, 河野 文昭
    2005 年 28 巻 2 号 p. 97-102
    発行日: 2005年
    公開日: 2025/06/18
    ジャーナル フリー
    In the field of maxillofacial prosthetics, the pivotal function of which is to enhance the functional rehabilitation of patients, substantial attention has been paid on how to assess the functional rehabilitation in question, as seen in the literature. Assessment criteria, however, seem to differ widely from institution to institution.
    Twenty-six papers which appeared in Journal of Maxllofacial Prosthetics (1995-2004) were surveyed from the point of view of functional rehabilitation, and the following results were obtained:
    1. The masticatory function was characteristically assessed using a questionnaire asking what foodstuffs the patient could eat.
    2. The speech function was characteristically assessed by means of a speech intelligibility test.
    3. The swallowing function was characteristically assessed by means of a water drinking test.
    4. Half of the papers surveyed seemed to use a reliable criterion, whereas the rest seemed to use a somewhat less reliable criterion.
  • 宮前 真, 尾澤 昌悟, 佐藤 徹, 天野 優一郎, 田中 貴信
    2005 年 28 巻 2 号 p. 103-108
    発行日: 2005年
    公開日: 2025/06/18
    ジャーナル フリー
    Various mandibular movements of patients who have undergone mandibulectomy in the past are unique. The closure pathway of mandibular movement is quite different from that of nonsurgical patients. Viewed from the frontal plane, the closure pathway is angular rather than vertical on the terminal occlusal position of mandibular movements. The normal articulator’s movement pathway is vertical. Generally, such a pathway is not suitable for patients suffering from bone defects. We have manufactured a trial version of a new type of articulator. A brief outline of our new type of articulator and a clinical case is reported.
第10回教育研修会講演抄録
第10回教育研修会座長総括
第22回学術大会抄録
第22回総会・学術大会報告
feedback
Top