Zairyo-to-Kankyo
Online ISSN : 1881-9664
Print ISSN : 0917-0480
ISSN-L : 0917-0480
Volume 58, Issue 3
Displaying 1-4 of 4 articles from this issue
Commentary
Review
  • Kazuaki Zen
    2009 Volume 58 Issue 3 Pages 82-85
    Published: 2009
    Released on J-STAGE: September 05, 2009
    JOURNAL FREE ACCESS
    Based on the PIANC PTC-II WG31 report1), the LCM of port structures has been introduced in Japan2)-6). Especially, the two repair options with equal lives at the Kamsar Port are economically compared using the Present Worth (PW) method. In present worth analysis, the PW is calculated at the Minimum Attractive Rate of Return (MARR), which is an inflation-free interest rate. When inflation occurs, the effect of inflation on the PW method must be examined.
    Since a present worth comparison involves calculating the equivalent present value of all future cash flows for each option, the PW of the options must be compared over the same number of years and end at the same time. The PW comparison of options with equal lives is straightforward. When options being compared have different lives, the Annual Worth (AW) method of comparing options is often preferred to the PW method, because AW comparison is performed for only one life cycle.
    In this report, the effect of inflation on the PW method is considered using the data of the Kamsar Port in the WG31 report, and the application of the PW and AW methods to unequal-life options is shown.
    Download PDF (239K)
Research Paper
  • Shinobu Suzuki, Yutaka Yamada, Kozo Kawano
    2009 Volume 58 Issue 3 Pages 99-104
    Published: 2009
    Released on J-STAGE: September 05, 2009
    JOURNAL FREE ACCESS
    The survey results of recent 120 leakage accidents showed that most of erosion corrosion failures of copper tubes in hot-water forced circulation system have been experienced at the downstream of joints of the return tubes. This tendency was the same as that of the research in 1996. The erosion corrosion of copper tube was observed when the concentration of dissolved oxygen in the hot-supply water was supersaturated and higher than that in supplied tap water. Therefore, it was presumed that erosion corrosion of copper tube was caused by the bubbles formed by pressure change in hot-water forced circulation system. The results of Computational fluid dynamics (CFD) simulations and the observation of the flow pattern in the model plumbing equipment showed that the locus of the micro-bubbles affect of the erosion corrosion of copper tube. According to the Young-Laplace equation, more small bubbles have high pressure in inside of the bubble, and maintain as the bubble without coalesce or collapse of bubbles. Consequently, it could be considered that erosion corrosion of copper tube occurred and propagated when the protective films formed on the tubes surfaces were continuously broken by micro-bubbles.
    Download PDF (585K)
  • Lei Wang, Tadashi Shinohara, Bo-Ping Zhang
    2009 Volume 58 Issue 3 Pages 105-110
    Published: 2009
    Released on J-STAGE: September 05, 2009
    JOURNAL FREE ACCESS
    Corrosion behavior of AZ31 magnesium alloy in dilute NaCl solutions was studied by electrochemical techniques. Its surface film was chemically characterized by X-ray diffraction (XRD). A corrosion map in terms of electrode potential and chloride concentration [Cl] was obtained by using electrochemical measurements. With the map, passivation and corrosion zones were determined. The passivation zone was found to become narrow with the increasing of [Cl] . The values of Eocp, open-circuit potential, in nondeaerated NaCl solutions were in the passivation zone when [Cl] <0.2 M and in the corrosion zone when [Cl] ≥0.2 M. The reduction reactions of dissolved oxygen and hydrogen evolution worked as cathodic reactions in nondeaerated solutions. By XRD analyses, Mg(OH)2, magnesium hydroxyl carbonate, and MgO were the dominant products in the corrosion zone, whereas magnesium hydroxyl carbonate and MgO were the main components in the passivated film.